OBERHEIM SYNTH group photo

Yahoo Groups archive

OBERHEIM SYNTH

Index last updated: 2026-04-28 23:39 UTC

Message

Re: [oberheim] Re: Matrix-1000 Original RAM sysex

2011-01-21 by Paul Cunningham

right... your sysex file is probably more like a series of patch change and sysex dump messages without any bank select commands. you can simply select patch 100, push the bank lock button and then send your file. this allows you to load any set of programs into either bank, which is more useful, especiallly if you are trying to load any of the other banks (200-900) into ram... -pc

On Jan 21, 2011, at 2:37 PM, wolzow <margus.kliimask@...> wrote:

> Hi,
> 
> 
> First, there is no Send All sysex command in M-1000 MIDI spec. The 27K file is a set of 100 (ie. 1 bank) individual Single Patch Data sysex commands: single patch = 275 bytes transmitted. You have to set the active bank first, the following sysex commands assume this bank. It's not a problem of M-1000, MIDI specification simply is limited to patch numbers 0..127 only, if a device allows more, it has to use banks.
> 
> Pls see the correct sysex docs (there are numerous errors in the printed manual) here:
> 
> http://www.wolzow.com/analog/m1k-midi-spec.htm
> 
> BTW, there's a note: "A gap of at least ten msec should be allowed between patches when sending
> multiple patches to the M-1000."
> 
> 
> On Fri, Jan 21, 2011 at 9:00 PM, cyllall <cyllall@...> wrote:
>  
> Hi,
> The manual says the Matrix-1000 doesn't need to be in any special mode to receive a patch dump,... it should switch banks automatically? 
> 
> Anyway, I dumped patches 200-299 from my Matrix and the sysex file was @27KB, the same size as the original RAM file in the files section here. I take it then that 100-199 is missing from that file?
> 
> Cheers
> 
> 
> 
> --- In oberheim@yahoogroups.com, Paul Cunningham <paul@...> wrote:
> >
> > the sounds on the matrix-1000 are organized into banks of 100... before you load up the 100-199 bank, change your bank to bank 1 and turn on bank hold, and they should load into the correct location. -pc
> > 
> > On Jan 21, 2011, at 11:55 AM, "cyllall" <cyllall@...> wrote:
> > 
> > > Hi,
> > > I've sent the sysex file to my M-1000 for the original RAM patches, but only 000-100 are there, 101-199 are missing. Am I doing something wrong, do I have to adjust the timing of the packets?. I used MIDIOX.I recently re-initialised the M-1000 after changing the battery.
> > > Thanks
> > > Martin
> > > 
> > >
> >
> 
> 
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.