Hi I am having an issue that seems very similar to yours. There is a diagnostics setting inside the M100, here: http://www.retrosound.de/Matrix-1000%20Service.htm THis lets you see which oscillator is not working properly. Then I suggest you swap the CEM chips between the faulty one and one of the others....and if the diagnostics say that your problem is with the same oscillator as before, it is NOT the CEM chip but some logic circuit connected to it. The CEMs are easily swapped using a flat screwdriver pr similar, they are not soldered. I did that, it was not was CEM chip, now I have turned the unit over to a repair guy to have it fixed :-/ regards HÃ¥kon --- In oberheim@yahoogroups.com, "dearsharps" <dearsharps@...> wrote: > > Is this the best source for cem3396 these days? > http://www.maad.net/ms6/index.html > > On my M1000, one of the voices only plays one osc, so I'm sure it must be a half-dead cem3396. Narrow body for the Matrix 1000 right? > > Thanks! >
Message
Re: CEM3396 source?
2013-05-31 by hawkberg
Attachments