Re: [oberheim] Re: Autotune on OBXa suddenly shutting down all voices

2015-07-25 by richtrix@...

Thanks yet again Bob for your help. You are a treasure in this Yahoo! community.

So the results are strange. I scoped pin 10 (clock, according to the internet) of U118, a 4021B, and when unstimulated it simple read 5 volts DC. If ever I hit a key and triggered a note a whole slew of strange signals would ensue. When hitting the autotune button I would get approximately the same resulting signals. I've tried to capture some of the madness in a series of screenshots attached. Notice these shots are mostly less than one second apart.

Any thoughts? Is this normal? Doesn't seem normal.

Sincerely,
Rich Clarke