Can you offer an explanation as to why I can get the bank change sysex to work and not the parameter adjustment? For example, I am sending F0 10 06 06 54 00 F7 to try to get Env. 1 release time to zero. I note that the manual says that the values are "sign extended from 6 bit to 7 bit". Does that mean the value byte is not literal? Thank you. Peter Quoting Margus Kliimask <margus.kliimask@...>: > Wrong. This is a command from Matrix-6/6R sysex implementation, M-1000 > is different. On an M-1000 you need not do this, nor does this command > get processed on M-1000. check out the page you referred. > > Regards, > Margus > > On Wed, Aug 5, 2009 at 3:53 PM, > bernard.escaillas<bernard@...> wrote: >> >> >> You have to send a message once to enable 'remote sysex'. >> >> This message is F0 10 06 05 F7 >> >> Note: the Matrix1000 has some bugs... >> Read more here: http://wolzow.mindworks.ee/analog/m1k-firmware.htm >> >> Be careful no to send sysex messages to fast or you will crash the Matrix... >> Even if MIDI bauds are always the same, today midi port buffers are a lot >> faster than in the 80's ;) >> >> Have fun >> >> > > > ------------------------------------ > > Yahoo! Groups Links > > > >