done. added hex values (in brackets) for easy reference (see
http://wolzow.mindworks.ee/analog/m1k-midi-spec.htm ).
regards,
margus
On Wed, Aug 5, 2009 at 10:51 PM, Margus
Kliimask<margus.kliimask@...> wrote:
> hmm... aren't you intermixing hex and decimal here? M-1000
> documentation shows the parameter numbers in DEC. your sysex string
> below should affect parameter 54 HEX (84 DEC, 'LFO 1 Initial
> Amplitude'). 54 DEC ('Env 1 Initial Release Time') is 36 HEX so the
> command F0 10 06 06 36 00 F7 (Note! F7 not 7F!) should do the trick.
>
> i guess i need to add hex codes to my page as well
> (http://wolzow.mindworks.ee/analog/m1k-midi-spec.htm).
>
> hope this helped,
> margus
>
> On Wed, Aug 5, 2009 at 6:59 AM, stublito<ogusa@lava.net> wrote:
>>
>>
>> Can't seem to get my new (to me) M1000 to respond to sysex paramter changes
>> embedded in a MIDI track.
>>
>> I do have the bank select sysex working perfectly, the bank unlock also.
>>
>> The manual says it's F0 10 06 06 <parameter> <value>. No luck. For instance,
>> F0 10 06 06 54 00 7F has no effect on Env 1 decay.
>>
>> I'm an experienced sysex programmer, I have my Roland analog stuff obeying
>> my every whim. Any suggestions?
>>
>> Thanks
>>
>> Stublito
>>
>>
>Message
Re: [oberheim] Matrix 1000 Sysex Real Time Parmeter Edit Not Working
2009-08-07 by Margus Kliimask
Attachments
- No local attachments were found for this message.