At 2:02 Uhr +0000 27.01.2011, Alexis V. Rogers wrote: > I rechecked the connections and everything was good. The battery voltage was > low, however, so I swapped in a new one. Now, the Octave switch and the > Program 1 LED are back to normal. But, the VCA Attenuator is still not > working. The switch tests good, and so do the diodes connected to it. I've > also checked the verified the connections from DO3 to the KLM-367. Do you have continuity of D03 from the switch through KLM-369 to KLM-367? I just had a Polysix with a non-working EG mode switch and a problematic attenuator; turned out that a trace on KLM-369 (the left board) was broken (in my case P10 was the culprit). Both KLM-370 and 369 can be affected by battery leakage.
Message
[PolySix] Re: Polysix Issues with: VCA / Octave Switch / Program 1 LED
2011-01-27 by Malte Rogacki