Yes, I do have continuity on DO3 from the switch to all points. --- In PolySix@yahoogroups.com, Malte Rogacki <gacki@...> wrote: > > At 2:02 Uhr +0000 27.01.2011, Alexis V. Rogers wrote: > > I rechecked the connections and everything was good. The battery voltage was > > low, however, so I swapped in a new one. Now, the Octave switch and the > > Program 1 LED are back to normal. But, the VCA Attenuator is still not > > working. The switch tests good, and so do the diodes connected to it. I've > > also checked the verified the connections from DO3 to the KLM-367. > > Do you have continuity of D03 from the switch through KLM-369 to KLM-367? > > I just had a Polysix with a non-working EG mode switch and a problematic > attenuator; turned out that a trace on KLM-369 (the left board) was broken > (in my case P10 was the culprit). Both KLM-370 and 369 can be affected by > battery leakage. >