> > > > > > > At 2:02 Uhr +0000 27.01.2011, Alexis V. Rogers wrote: > > > I rechecked the connections and everything was good. The battery > voltage was > > > low, however, so I swapped in a new one. Now, the Octave switch > and the > > > Program 1 LED are back to normal. > In the first place, that's pretty strange, since the battery affects neither of those. > But, the VCA Attenuator is still not > > > working. The switch tests good, and so do the diodes connected to > it. I've > > > also checked the verified the connections from DO3 to the KLM-367. > > > Look at IC35 on the CPU board -- pins 4, 7, 14 and 13 should be seeing D04 through D07. Pin 5 should be seeing the P25 line from the CPU. Turning the rotary switch should show varying outputs on pins 2, 10, 1 and 11. ~G > > > > [Non-text portions of this message have been removed]
Message
Re: [PolySix] Re: Polysix Issues with: VCA / Octave Switch / Program 1 LED
2011-01-29 by klosmon