Yahoo Groups archive

Emu XL-7 & MP-7 User's Group

Index last updated: 2026-04-29 00:09 UTC

Message

Re: XL7 as a slave

2005-11-27 by steve_the_composer

This problem seemed at first glance an easy one to diagnose. However, 
since I haven't done much with E-Mu sequencer recording, it took a 
while. Since I don't have an electribe, I used Sonar to send data on 
16 channels to my E-Mu sequencer [P2500]. 

I hope this helps:

Relevant MIDI settings:
---BASE TEMPO: ext
---RECHANNELIZE INPUT: off 
---EXTERNAL SONG START/STOP: accepted
---MIDI IN CHANNELS: 1 to 16: A
---MIDI ENABLE channel 16A: off
---RECEIVE PROGRAM CHANGE channel 16A: off

PATTERN EDIT settings [I used T01]:
---CHANNEL ASSIGN Channel: MultiA Dest: Int

NOTE:
ALL Notes were recorded, including those on channel 16, but on 
recording and playback, the channel 16 data was not sent to the 
internal synth engine. 

If you don't mind having the channel 16 data recorded as long as it 
doesn't play your E-Mu, the solution above should work for you.

If this doesn't meet your specific needs, I'd recommend getting some 
kind of programmable filtering device. For  example, I have see MOTU 
8x8 midi routers [Express XT] (among others) on e-bay. The parallel 
port version used to go for around $70-$85. The usb port version is 
more expensive. With either you have 8 user slots to configure 
different routings using computer software. 


--Steve  


--- In xl7@yahoogroups.com, "xl7mo" <apekup@h...> wrote:

> My brother and I are in the same band he is on a 'Electribe ER-1' 
and I'm on the 'xl7'. 

My 
> brother is the drummer and the 'Electribe ER-1' is the master so he 
controls the 

tempo(BPM). 
> My xl7 is the slave. so far so good. He controls start/stop and 
sets the tempo.
> My problem is that when I want to record something in realtime, the 
midi data from the 
> 'Electribe ER-1' is recorded too. The er-1 is on channel 16. I'm 
not using channel 16. 
> Rechannelize input is set to off. Enable midi for channel 16 is set 
to off. But still it is 
> recording the mididata from the 'Electribe ER-1'.
> After a day work and 3 times reading the manual we could not fix 
this. Please help!
> 
> EMU xl7 version 2.0
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.