Dear Sirs, I have a question about the double bus fault . In a dokumentation (M68331/68332TUD/D) "An introduction to the MC68331 and Mc68332" I found the following statements: "If the double bus fault has been disabled by clearing the HME-Bit in the system protection register, the MCU will remain halted indefinitely and must be reset externaly. " Is it possible to reset the MCU with the enabled watchdog if an double bus fault had occured. Or is the watchdog halted, too. So the watchdog can not reset the MCU. "After a double bus fault occurs, the MCU drives the HALT line low, and can only restarted by a reset." When I want to watch the HALT signal at the HALT pin, is it necessary to set the HME-BIT ? I do not think so, but am not shure. Best regards Joachim
Message
double bus fault
2003-10-21 by Octagon Entwicklung
Attachments