Re: QTR Create ICC Error Message

2010-05-20 by erutchick2002

Thanks, Paul.  We'll try that.


--- In DigitalBlackandWhiteThePrint@yahoogroups.com, "pr_roark" <roark.paul@...> wrote:
>
> "na_goodman" <nagoodman@> wrote:
> 
> > 
> > After dropping our .txt file on the QTR-Create-ICC droplet, we are receiving an error message as follows: Cannot create ICC profile; LAB values not in order.
> > 
> > We read the 21x4 grayscale target with the EyeOne.  Any help or suggestions will be greatly appreciated.
> 
> 
> 
> I get that error only when my single 21-step test file shows posterization or has an insufficient (very small) increase in density (lowering of Lab L) from one step to the next.  
> 
> I don't know if Create ICC supports the multi-sampled random reads.  Even if it does, it's probably harder in those to see where the problem is.  Try printing and reading a single, in-order, 21-step test file.
> 
> Paul
> www.PaulRoark.com
>