Yahoo Groups archive

Digital BW, The Print

Index last updated: 2026-04-28 22:56 UTC

Message

Re: [Digital BW] R1800/3mk failure (my error) HELP!!!

2008-10-22 by pr_roark

Colin wrote:
>
> ... I use Eboni in the Y, MK and PK slots and PKN in the R, B 
> and C slots.  I seldom get all working properly ...

I found my 1800 with both the 3-MK and 3-PKN in it tended to clog, 
whereas I don't have clogs with the 3MK and Eboni-6 or just clear 
base in it.  I think it might have been just too much PK and MK, with 
insufficient dilute ink to rinse the pad.  


> ... I do not think I have particulate clogs.

I suspect the "clogs" I was experiencing were caused by junk from the 
parking pad sticking to the surface of the head, but I didn't 
continue the experiments long enough to know what exactly was going 
on. 

Paul