2006-05-16 by Florian Anwander

Hi Dieter

The idea of such an interface module, would be to provide not only the 
controll lines which are used for a A155, but all available.
e.g you could use the adress data as gates for envelopes or what ever.

btw: the outputs should be made as multiples (at least two outs per line)

Florian

Dieter Doepfer wrote:

>>-----Ursprüngliche Nachricht-----
>>Von: Doepfer_a100@yahoogroups.com
>>[mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von Bakis Sirros
>>Gesendet: Dienstag, 16. Mai 2006 15:14
>>An: Doepfer_a100@yahoogroups.com
>>Betreff: Re: AW: [Doepfer_a100] any more ideas for exotic future A100
>>modules? -> Modular Sequencing System
>>
>>
>>hello florian, dieter,
>>ok, now i'm confused.
>>the internal a155 addreses and a155, a154 clocks are 3
>>bits(ao,a1,a2) right? how can an expansion nmodule for
>>these could be 4 bits then?
> 
> 
> In addition to the addresses a0, a1 and a2 you also need the clock signal.
> It is used for the trigger outputs (the clock pulsewidth is responsible for
> the length of the trigger pulses).
> 
> a3 is only necessary of two A-155 are in use (the A-154 has details
> concerning the usage of A3 with VC switches).
> 
> Best wishes
> Dieter Doepfer
> 
> 
> 
> 
>  
> Yahoo! Groups Links
> 
> 
> 
>  
> 
> 

-- 
Florian Anwander                  |ConSol
Tel.   +49(89)45841-133           |Consulting&Solutions Software GmbH
Fax    +49(89)45841-111           |Franziskanerstr. 38, D-81669 München
email: florian.anwander@consol.de |http://www.consol.de