Re: 5V Low-Cost Adapter questions

2007-12-14 by jalmari3

Thank you for the quick replies.

Best regards
Jari Jokinen

--- In Doepfer_a100@yahoogroups.com, Florian Anwander 
<Florian.Anwander@...> wrote:
>
> Hi
> 
> one could add a larger cooling device to the regulator, but I 
assume 
> this would cause mechanical problem in transport (too much mass).
> 
> Florian
> 
> selfoscillate wrote:
> > hello chuck,
> > 
> > only one ad5 is allowed per row.
> > as long as the total 5 volts consumption of the modules
> > doesn't exceed 100ma you can use more than 1 module
> > with the ad5. in the example below (a113 and a190)
> > the 5 volts consumption is 150 ma, therefore you need
> > two ad5.
> > 
> > best wishes
> > 
> > ingo
> > 
> > 
> > 
> > --- In Doepfer_a100@yahoogroups.com, "charles graef" 
> > <vogelscheiss@> wrote:
> > 
> >>Sorry, I'm confused -- you're saying that the A-100AD5 will only 
> > 
> > permit one
> > 
> >>5V module in the row in which it's installed?
> >>
> >>--Chuck
> >>
> >>-----Original Message-----
> >>From: Doepfer_a100@yahoogroups.com 
> > 
> > [mailto:Doepfer_a100@yahoogroups.com] On
> > 
> >>Behalf Of hardware@
> >>Sent: Friday, December 14, 2007 10:12 AM
> >>To: Doepfer_a100@yahoogroups.com
> >>Subject: AW: [Doepfer_a100] 5V Low-Cost Adapter questions
> >>
> >>
> >>>I have two 5V Low-Cost Adapters (A-100AD5). I have previously 
> > 
> > used them
> > 
> >>>with A-113 and A-190 installed in separate A-100G6 cabinets.
> >>>
> >>>Now I am going to put A-113 and A-190 into same cabinet. Looking 
> > 
> > at the
> > 
> >>>power consumption figures it appears, that two A-100AD5 are still
> >>>needed. Just to make to make sure, I would like to ask, how 
> > 
> > should the
> > 
> >>>A-100AD5:s be installed, when
> >>>- A-113 and A-190 are in the same row/power rail.
> >>
> >>Sorry, that's not possible as only one A-100AD5 is allowed for 
each 
> > 
> > bus
> > 
> >>board.
> >>
> >>
> >>>- A-113 and A-190 are in different rows.
> >>
> >>That's the right solution. Simple connect one A-100AD5 on each 
bus 
> > 
> > board.
> > 
> >>Best wishes
> >>Dieter Doepfer
> >>
> > 
> > 
> > 
> > 
> > 
> >  
> > Yahoo! Groups Links
> > 
> > 
> > 
> > 
> 
> -- 
> Florian Anwander                  |ConSol
> Tel.   +49(89)45841-133           |Consulting&Solutions Software 
GmbH
> Fax    +49(89)45841-111           |Franziskanerstr. 38, D-81669 
München
> email: florian.anwander@... |http://www.consol.de
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.