Hi Wolfgang Can you please tell me how to test three voltages are ok? -12V/+12V/+5V on A-100P thanks David On 8/06/2008, at 10:22 AM, wolfgthiel wrote: > Hi David > > Was the A-190 working before you did the reset? > Have you checked if all three voltages are ok? -12V/+12V/+5V. > I don't think there is a fuse in the A-190 modul (just had a look at > my > one)and I'm not familiar with the Doepfer power supply. In general you > could take the fuse out and replace it with a new one of the same > rating, or if you familiar with a multimeter take the fuse out and > check continuity of the fuse with an ohm meter. > Good luck. > > Wolfgang > > --- In Doepfer_a100@yahoogroups.com, David Bulog <d2ba@...> wrote: > > > > I went do a full reset of the A-190 by powerup while holding buttons > > 1-4 on power up > > When I powered the unit on the lights on the A-190 came on > momentarily > > and then no power. > > Has anyone had a similar issue > > > > BTW -How do I check if fuse is vlown > > > > thanks David > > > > > > > > > > [Non-text portions of this message have been removed] > > > > > [Non-text portions of this message have been removed]
Message
Re: [Doepfer_a100] Re: A-190 and reset proceedure
2008-06-08 by David Bulog
Attachments