From the theory it should make no difference because each group with the four blade terminals is connected to the same signal (-12V, GND or +12V) because the four terminals of each group are shortened. I have no idea why wiring them identically solved the problem. Anyway - it's good tp know that now everything is fine. Best wishes Dieter Doepfer > -----Ursprüngliche Nachricht----- > Von: Doepfer_a100@yahoogroups.com [mailto:Doepfer_a100@yahoogroups.com] > Gesendet: Samstag, 4. Juli 2015 09:14 > An: Doepfer_a100@yahoogroups.com > Betreff: [Doepfer_a100] Re: trouble with VC patching to second G6 frame > > > > > in short the grounds were wired differently on each frame. The solution was to wire them identically. > > Here is what they looked like before (problem state). I made them both look like the right side photo. > > https://groups.yahoo.com/neo/groups/Doepfer_a100/photos/albums/1830938856/lightbox/448632445?orderBy=ordinal&sortOrder=asc > &photoFilter=ALL#zax/448632445 >
Message
AW: [Doepfer_a100] Re: trouble with VC patching to second G6 frame
2015-07-06 by yahoo@doepfer.de
Attachments
- No local attachments were found for this message.