First of all I'd recommend to remove all modules to make sure that the fault is not caused by another module. If you are a bit familiar with electronics you may alternatively disconnect the bus boards from the power supply and look at the control LEDs of the power supply. If the -12V are still missing without anything connected the supply is faulty. From your message I cannot see which power supply you have in use. If it's an A-100PSU2 probably the -12V voltage regulator is defective. If it's an A-100PSU3 the -15V module may be defective or the -12V voltage regulator. The following link to our website may be also helpful: www.doepfer.com > English > FAQ > A-100 > My A-100 system does no longer work Best regards Dieter Doepfer __________________________________________________________________ Doepfer Musikelektronik GmbH Geigerstr. 13 82166 Graefelfing / Germany registered in Munich/Germany, commercial registry HRB 97 399 CEO's: Sibille Heller, Dieter Doepfer European VAT ID No. DE129329318 website: www.doepfer.com __________________________________________________________________ Best wishes Dieter Doepfer > Later on I noticed it was not only this module with strange > behaviour...even some modules didn't even work anymore in that > case.....so the final point is that I have no more minus 12 > Volt...! That's the reason for all. > Anybody an idea what to do know? > Thanks, > Danny