Re: [Doepfer_a100] Re: A-134-1 problem

2017-07-17 by Florian Anwander

Hi Danny

Am 17.07.2017 um 08:18 schrieb syndromeda@telenet.be [Doepfer_a100]:
> Anybody an idea what to do know?
1.) Switch off the system
2.) remove the A-134-1 and disconnect it from the supply bus
3.) switch on the system and check whether the -12 volts are available again
      * if yes -> the module needs repair
      * if no
4.) switch off the system
5.) remove all modules from the rack, do not keep any module connected 
to the power bus
6.) switch on the system and check whether the -12 volts are available
      * if no -> shot on the supplybus or powersupply broken
      * if yes
7.) switch off the system
8.) mount the first module
9.) switch on the system and check whether the -12 volts are available
      * if yes -> do the loop from 7.) with the next module
      * if no -> you have found the module which causes the -12 volts to 
break down.

Florian


-- 