> -----Ursprüngliche Nachricht----- > Von: Doepfer_a100@yahoogroups.com > [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von Bakis Sirros > Gesendet: Sonntag, 5. Juni 2005 11:35 > An: Doepfer_a100 group; Analogue Systems group > Betreff: Re: [Doepfer_a100] Re: Power ribbon cables > > > hello, > if i remember well, doepfer rack case have their > connectors installed is such a way so as the red > stripe of the ribbon cables to be downwards. > in the Analogue Solutions cabinets, the doepfer > connectors in their modules are in such a way > installed so as the red stripe to face upwards. btw, > the red stripe for doepfer and analogue SOLUTIONS > means pin1 and -12volts. > in the analogue SYSTEMS rack cases, their analogue > systems connectors have their connectors in such a way > so as their red stripe to mean 0volts. > dieter, bob, if i am wrong correct me, ok? > best regards, > bakis. For the A-100 everything is correct. The red stripe marks -12V and has always to face downwards. More details are available on our web site: A-100 Technical details A-100 Mechanical details A-100 manual introduction (pdf file A100_intro_e.pdf) in the manuals section Best wishes Dieter Doepfer
Message
AW: [Doepfer_a100] Re: Power ribbon cables
2005-06-06 by Dieter Doepfer
Attachments