Re: SD1 Power up.

2005-05-20 by numaniod2005

Thats basicly what I said.


--- In Ensoniq-VFX-SD@yahoogroups.com, john bluhm 
<falconjohnney@y...> wrote:
> Hi Tony. I had a problem, like the one you describe, on a VFX. The 
VFX has two circuit boards
> which control each half of the keyboard. They are connected 
together via a pair of headers. If
> the header pins become dirty, the keyboard will not function, and 
thus, the VFX would simply
> ignore the keyboard altogether.  The simple solution was to clean 
the pins on the headers. It
> then worked fine ever since.  If you have any questions, email me 
back.    John.
> 
> tjiyf <tjiyf@h...> wrote:
> I have a recurring problem on my Sd1, about 30% of the time when i 
> power up the keyboard does not get to the calibation notice so the 
> keyboard is not usable. I continue to switch the power on and off 
> somtimes up to 100 times before the keyboard will initilize.
> I then have to releod the O.S system and sounds etc. 
> Is there any thing i can do to prevent this.
> 
> Tony. 
> 
> 
> 
> 
> ---------------------------------
> Yahoo! Groups Links
> 
>    To visit your group on the web, go to:
> http://groups.yahoo.com/group/Ensoniq-VFX-SD/
>   
>    To unsubscribe from this group, send an email to:
> Ensoniq-VFX-SD-unsubscribe@yahoogroups.com
>   
>    Your use of Yahoo! Groups is subject to the Yahoo! Terms of 
Service. 
> 
> 
> 		
> ---------------------------------
> Discover Yahoo!
>  Stay in touch with email, IM, photo sharing & more. Check it out!

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.