Yes, it will measure dmax. Lmin=dmax in the scenario you described. You can easily convert L to density units with the appropriate formula (search the archive) if you wish, but it really isn't necessary. Colormunki will also strip read so you don't have to measure patch by patch, you just need to make a custom target to do this. Send me an email if you want a Colormunki QTR compatible 51 step gray target psd file. Carl On Jul 1, 2008, at 4:07 PM, John wrote: > Maybe I'm didn't make it clear..... Say I want to know the max. ink > limit of each channel, I print a 21-step Dmax test strip (from 0 to > 100) then measure each patches' Dmax e.g. let's assume it occurred at > 65% for this example then I know the inking limit occurred at 65% for > that channel. > > I did this with my previous spectro, as I'm thinking to get the > ColorMunki therefore need to know if it can do it. > > Thanks
Message
Re: [QuadtoneRIP] Re: Can ColorMunki measure Dmax?
2008-07-01 by Carl Schofield
Attachments