Yahoo Groups archive

QTR-Quadtone RIP

Index last updated: 2026-04-28 23:12 UTC

Message

Re: QTR - Epson 2200 - UT7 - Banding Problems

2008-08-20 by djon43

1) Try both adaptive hybrid and ordered dithers (bottom of QTR control
panel)

2) Try increasing ink loading (eg to 75)

3) If those don't work, forget MIS. QTR does fine with Epson pigments,
produces deeper blacks than UT7, equal neutrality, and will never clog
nearly as seriously. If you don't get reliably perfect nozzle tests
(eg 9 out of 10 times) problems will continue.

--- In QuadtoneRIP@yahoogroups.com, "eyewall" <eyewall@...> wrote:
>
> Everyone, I would really appreciate a solution. My printer has so
far gone through half of 
> my brand new $80 ink trying to fix a clog.
> 
> Please help.
> 
> --- In QuadtoneRIP@yahoogroups.com, "Paul Grant" <gphoto2@> wrote:
> >
> > I have the same problem here.  I just installed UT3D and used up
most of the
> > cartridges doing nozzle clean and checks...the tests are pretty
random.good
> > to bad to so so..
> > 
> >  
> > 
> > Any suggestions?
> > 
> >  
> > 
> > Paul
> > 
> >  
> > 
> > From: QuadtoneRIP@yahoogroups.com
[mailto:QuadtoneRIP@yahoogroups.com] On
> > Behalf Of eyewall
> > Sent: Tuesday, August 19, 2008 7:19 PM
> > To: QuadtoneRIP@yahoogroups.com
> > Subject: [QuadtoneRIP] Re: QTR - Epson 2200 - UT7 - Banding Problems
> > 
> >  
> > 
> > I just ran the nozzle check. It's clogged pretty badly. Cleaning
has no
> > effect whatsover. 
> > What should I do?
> > 
> > --- In QuadtoneRIP@yahoogroups.com
<mailto:QuadtoneRIP%40yahoogroups.com> ,
> > "eyewall" <eyewall@> wrote:
> > >
> > > By the way, I'm using Hahnemuhle Photo Rag.
> > > 
> > > --- In QuadtoneRIP@yahoogroups.com
<mailto:QuadtoneRIP%40yahoogroups.com>
> > , "eyewall" <eyewall@> wrote:
> > > >
> > > > Hi all--
> > > > 
> > > > I just got a new UT7 cartridge inkset. It's working well
(variable tone
> > is nice) but it is 
> > > > exhibiting pretty bad banding. I'm using the curves that came
with QTR
> > along with the 
> > > QTR-
> > > > Matte-Profile when I go to print.
> > > > 
> > > > Any help would be greatly appreciated.
> > > > 
> > > > Thanks,
> > > > 
> > > > Peter
> > > >
> > >
> > 
> >  
> > 
> > 
> > 
> > [Non-text portions of this message have been removed]
> >
>