2011-08-28 by Michael King

Sean, indeed it appears that strip measurements requires the dongle. Sorry
about that.

I guess you'll need to use colorport
https://xrite.co.uk/product_overview.aspx?ID=719&Action=support&SoftwareID=1032

Mike

On 27 August 2011 23:35, spsguru <spsguru@...> wrote:

> **
>
>
> OK- now I am stumped.
> The Measure Tool grays out the Start button when I choose anything other
> than manual - so I cannot scan strip without gaps
>
> And the manual tool does not begin on white but right on the patch.
>
> I must be missing something obvious but dont know what it is - cannot you
> not scan Strips without a dongle?
>
>
> Sean
>
> --- In QuadtoneRIP@yahoogroups.com, Michael King <drmrking@...> wrote:
> >
> > yep you got it - it will tell you if it reads the line correct.
> > if not try starting with a bit more white and ending with a bit more
> white.
> >
> > you need to press the button on the i1 device to start each line.
> >
> > good luck
> >
> > On 27 August 2011 01:20, spsguru <spsguru@...> wrote:
> >
> > > **
> > >
> > >
> > > Mike - this is just the kind of insight I was hoping for...can never
> seem
> > > to find this stuff in a manual.
> > >
> > > No - I was scanning using Patches not strip
> > >
> > > So - Strip without Gaps - start on white end on white - for each line -
> > > correct?
> > >
> > >
> > > thank you
> > > Sean
> > >
> > > --- In QuadtoneRIP@yahoogroups.com, Michael King <drmrking@> wrote:
> > > >
> > > > Seanh,
> > > >
> > > > ok so just to confirm - you are printing the 21 x 4 random target
> from
> > > the
> > > > QTR eye-one folder - correct?
> > > > Without changing its size or anything else - correct?
> > > >
> > > > then you load the 24 x 4 random txt file into measure tool and select
> > > "mode:
> > > > strip without gaps".
> > > > Then starting at the top left of the target where it says "Beg" you
> scan
> > > the
> > > > target smoothly from left to right for one line and the come back to
> the
> > > > beginning of the next line and scan from left to right again etc.
> > > >
> > > > Note you must start the scan on the white paper before the target
> line
> > > and
> > > > end on the white paper after the target line.
> > > >
> > > > Mike
> > > >
> > > >
> > > >
> > > > On 26 August 2011 21:13, spsguru <spsguru@> wrote:
> > > >
> > > > > **
> > > > >
> > > > >
> > > > > Mike
> > > > >
> > > > > Thank you for the tip.
> > > > >
> > > > > I did install measure. After multiple tries I keep getting the out
> of
> > > order
> > > > > error using the 21x4 patch
> > > > >
> > > > > When I look at the sampled strip just prior to export it looks like
> the
> > > > > printed strip so I think I am measuring then right patch
> > > > >
> > > > > But like I said after about 6 tries I keep getting the error
> > > > >
> > > > > Any ideas how to get past this?
> > > > >
> > > > > Thank you
> > > > > Sean
> > > > >
> > > > > --- In QuadtoneRIP@yahoogroups.com, Michael King <drmrking@>
> wrote:
> > > > > >
> > > > > > I don't think iprofiler supports spot measurements. You need the
> old
> > > > > xrite
> > > > > > "measuretool". It comes as part of the discontinued profilemaker5
> > > > > download,
> > > > > > and the features you need work without a dongle (i.e. free). You
> can
> > > get
> > > > > it
> > > > > > here ...
> > > > > >
> > > > >
> > >
> http://www.xrite.com/product_overview.aspx?ID=757&Action=support&SoftwareID=931
> > > > > >
> > > > > > I think you can choose what to install - so just install
> measuretool.
> > > > > >
> > > > > > Good luck.
> > > > > >
> > > > > > Mike
> > > > > >
> > > > > > On 26 August 2011 01:56, spsguru <spsguru@> wrote:
> > > > > >
> > > > > > > **
> > > > > > >
> > > > > > >
> > > > > > > Hi all
> > > > > > >
> > > > > > > I am new to creating icc profiles
> > > > > > >
> > > > > > > I just purchased i1 Pro Basic kit
> > > > > > >
> > > > > > > The software it comes with is i1 Profiler that automatically
> > > creates
> > > > > > > targets
> > > > > > >
> > > > > > > I cannot find a way to just get to the measuring device and
> take
> > > the
> > > > > spot
> > > > > > > measurements I think I need to for creation of ICC - or to load
> in
> > > the
> > > > > > > target the way the Roy's icc instructions dictate for the old
> > > software.
> > > > > > >
> > > > > > > Any help on creating icc profiles with i1 Pro basic kit would
> be
> > > > > > > appreciated
> > > > > > >
> > > > > > > thank you
> > > > > > > Sean
> > > > > > >
> > > > > > >
> > > > > > >
> > > > > >
> > > > > >
> > > > > > [Non-text portions of this message have been removed]
> > > > > >
> > > > >
> > > > >
> > > > >
> > > >
> > > >
> > > > [Non-text portions of this message have been removed]
> > > >
> > >
> > >
> > >
> >
> >
> > [Non-text portions of this message have been removed]
> >
>
>  
>


[Non-text portions of this message have been removed]