Message

Re: [analogue-sequencer] How to load the sysex file

2004-03-16 by Colin f

> What is the procedure to load an OS into the P3?
>
> Stupid question probably, but I just can't get it to work, getting all
> the time a "bad block" message on the P3 asa I try to upload the
> latest revision.

That can happen if you have your sysex app configured so that the handshake
response from P3 to each block is soft-thru'ed back to P3.
Try doing it with just the midi out from your PC connected to the midi in on
P3, and no return lead.
What app are you using ? Midiox ?
You also need to be sure there is a delay of around 100ms between sysex
blocks to give P3 a chance to write each flash block.

Cheers,
Colin f