Yahoo Groups archive

Analogue-sequencer

Index last updated: 2026-04-28 23:15 UTC

Message

Re: direction/shift question..

2003-11-20 by ch.³l

hi Colin,
> Oops...
> I'm aware of a similar problem with paste.
i think the FTS setting could be in on this 'bug' as well; i was 
trying to trigger a sample set to G, in a pattern in a part with FTS 
set to none. the pattern i was editting was 'saved to' from a pattern 
in a part in which the FTS was set to arabian scale, in which G is 
not played. the sample played fine when triggered from the attatched 
keyboard, but not when played from the P3. the note was programmed on 
step 3 of the pattern, which was the initially the first step, 
shifted right twice.
it triggered fine off step 2 though...and strangely enough, it also 
played on step 3 if step 2 was also set to the same note..
sounds like it's part of the same fault?
grtz chiel