Bc2000 (for the BCF2000 & BCR2000) group photo

Yahoo Groups archive

Bc2000 (for the BCF2000 & BCR2000)

Index last updated: 2026-04-28 23:16 UTC

Message

Re: [bc2000] Re: BCR2000/BC Manager/LIve 8 problems

2010-01-26 by Dan Berridge

Hi Royce,

Sorry for the delay in getting back on this one. Been working on it...

No, there is only a 1 in and one out on my PadKontrol, which is hooked up through USB to the computer. In Live I've set the PadKontrol port A as the Mackie Control, which works fine as simple transport.

"I take it you have connected the Midi out from the PC to the Midi In on the BC? 8)"

Well yes I have and I current DO get visual feedback. And I have Mackie Control over Live with my BCR. However I'm getting very stutteringcontrol of Live's .

Here's what I'm doing and hopefully you can tell me where I'm going wrong;

I have 2 midi interfaces running (PadKontrol and on my Prosonus Audio/midi card Both with one in and out). This is because I couldn't figure a way to get midi back from the PC In to the BCR without creating a midi loop!
So, my BCR output goes IN to my Presonus Input
And my BCR Input comes from my PadKontrol output

Now as I say, this works partially, but I'm getting crazy random midi messages messing all the controls up. This could be a separate problem.

What do you think??


On Wed, Jan 20, 2010 at 1:37 PM, rpcfender <rpcfender@yahoo.com.au> wrote:

Hi Dan



> So, an update.
> I am now using the BCR in midi mode S-3, connected into the Ins of my

Ins??? more than one?


> PadKontrol, which is hooked into Live as Mackie Control anyway (I use it for
> transport controls). This seems to work for Mackie emulation, with the
> "BCR=Live_ver4.1.syx" preset installed.
>
> HOWEVER, I am recieving no visual feedback on the BCR from Live. Is there
> some special way I should be hooking up the midi to recieve visual feedback?

I take it you have connected the Midi out from the PC to the Midi In on the BC? 8)

All the best
Royce




--
www.broadwayproject.co.uk
www.myspace.com/broadwayproject

Daniel Berridge
14 Bruce Avenue
Bristol BS5 6EF
UK
0044(0)7786371011

---------------------------------------------

This email is confidential and intended solely for the use of the individual or organisation to whom it is addressed. If you are not the intended recipient of this email, you should not copy, modify, distribute or take any action in reliance on it. If you have received this email in error please notify the sender and delete this email from your system.
This email and any attachments are also subject to copyright.
No part of them may be reproduced, adapted or transmitted without the written permission of the copyright owner.

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.