--- In bc2000@yahoogroups.com, Uwe Jülich <uwejuelich@...> wrote: > i get the two errors when trying to connect with reason. bc manager will > also not recognize the bcr. is there any chance to find out what those error > messages mean? See section 21.2 in "BC MIDI Implementation.pdf", available from http://home.kpn.nl/f2hmjvandenberg281/bc2000.html . Error numbers 6 and 22 indicate problems with the BCL sequences: In any BCL message sequence, each message has an internal index, and the BCF2000 and BCR2000 require these indexes to increment correctly (starting from 0). So for instance if there is a split followed by a merge in the signal path, a (correct) sequence with indexes 0, 1, 2 ... would be received as 0, 0, 1, 1, 2, 2 - which the receiving BCF/BCR won't accept. In any case there seems to be something fundamentally wrong about your connection setup. Is your BCR in the correct Operating Mode (S/U-1/2/3/4)? Hope this helps, Mark.
Message
Re: Err6 and Err22
2012-11-30 by Mark v.d. Berg
Attachments
- No local attachments were found for this message.