Thanks for you advice. In Windows XP all works as expected, I got this problems since Windows 7 64bit. Operation Mode is U-1. I'll test the unit again with XP tomorrow, so I can check it's ok.
thx
Von:
bc2000@yahoogroups.com [mailto:bc2000@yahoogroups.com] Im Auftrag von Mark v.d. Berg
Gesendet: Freitag, 30. November
2012 22:45
An: bc2000@yahoogroups.com
Betreff: [bc2000] Re: Err6 and
Err22
--- In bc2000@yahoogroups.com,
Uwe Jülich wrote:
> i get the two errors when trying to connect with reason. bc manager will
> also not recognize the bcr. is there any chance to find out what those
error
> messages mean?
See section 21.2 in "BC MIDI Implementation.pdf", available from http://home.kpn.nl/f2hmjvandenberg281/bc2000.html
.
Error numbers 6 and 22 indicate problems with the BCL sequences:
In any BCL message sequence, each message has an internal index, and the
BCF2000 and BCR2000 require these indexes to increment correctly (starting from
0).
So for instance if there is a split followed by a merge in the signal path, a
(correct) sequence with indexes 0, 1, 2 ... would be received as 0, 0, 1, 1, 2,
2 - which the receiving BCF/BCR won't accept.
In any case there seems to be something fundamentally wrong about your
connection setup.
Is your BCR in the correct Operating Mode (S/U-1/2/3/4)?
Hope this helps,
Mark.