Re: Machinedrum ext sync...

2006-08-23 by innerclock2004

Hiya,

Even though technically both units should follow song position -
because  Midi Clock is 24 ppq and you are hardware slaving from Live -
there is always the chance that you will lose midi clocks here and
there leading to odd/erratic sync in your hardware. Unless you are
certain of the stability of your PC midi sync out - you might be
better off slaving Live to either one of your Elektron boxes which
have ultra-reliable clocking. Also - are you using a thru box for the
sync or are you daisy chaining. Daisy chaining sync is a sure fire way
to cause problems. Get a powered thru box. Run your master sync into
the input and run all your slaves off the 'Thrus'. 

Hope this helps.

David

www.innerclocksystems.com