Yahoo Groups archive

Emax

Index last updated: 2026-04-28 23:23 UTC

Message

Re: Baldwin IKE CF addition mayhem

2012-02-21 by soundsubs

>Perhaps IC54, IC5 and check RN1 resistor networks in regards to floppy.
>>>For reference: 
IC54 (Philips 74HCT14N) is not socketed
IC5 (74SOON) is not socketed either
RN1 (F221/331GA 10-pin Resistor Network) 
No burn marks or anything physically wrong with them to the eye. 
I suppose its possible that the drive is bad, as it clicks with "disk not formatted" even with a floppy removed from it. 


The floppy ribbon cable-- which seems to be a 4N093-A01-- is just like this one: http://www.ebay.com/itm/DELL-5N051-GX150-GX240-GX260-GX270-CD-SFF-DRIVE-CABLE-CN-05N051-/380372017920?pt=LH_DefaultDomain_0&hash=item588ff06300

Not sure it can be modified?

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.