I had 5 EXS instruments instantiated and I wanted to automate the filter cutoff frequency. I put Logic in record and moved the knob with my mouse to record the data. When I went to play it back, I got no action from the EXS. When I looked at the Event list everything looked fine except that it didn't say anything in the info column (where it normally says EXS#xx). After further investigation I realized that the Low Cut filter that I had plugged in on that track had showed up in the list of Controller numbers 'cutting off' the regular EXS parameters. When I unplugged the Low Cut plug, then I saw the full list of the EXS parameters and the automation played back fine. I was wondering what the logic is with this type of setup. Can I not have any plug-ins on an EXS track that I want to automate? Is there a way to determine what Contollers a plug will use or if it should respond to MIDI data at all? Just wondering if any of you have run into this and found any possible workarounds. thanks, Philip