Re: [lpc2000] bug in JTAG implementation?

2005-11-14 by Dominic Rath

I've seen similar behaviour on a LPC2294 I've used to test with. I asked 
philips support, and they told me they don't know about any problems...

Anyway, as you said, it doesn't affect debugging, and during Capture-IR, the 
correct value of b0001 is being loaded, so that's fine and can be used to 
validate the communication.

Regards,

Dominic

On Monday 14 November 2005 22:27, Bhanu Nagendra Pisupati wrote:
> When a value is shifted into the scan select register of the Embedded ICE
> module of the lpc parts (through JTAG), ARM7TDMI documentation specifies
> that the binary value '1000' needs to be shifted out. However, after much
> ado I discovered that this is not the case in my lpc2214. This does not
> seem to affect any other aspect of JTAG debugging though. Has anybody else
> seen similar behaviour?
> -BNP

Attachments