Gus, I fear you may be 100% correct. SBHE is held high, sigh. I think you're buggered for 16-bit mode, mate. Perhaps Olimex didn't test the Ethernet interface in 16 bit mode, only 8 bit mode. It might have been useful if one of the INTRQ lines was connected up too. You might want to take a look at http://www.thearmpatch.com/lpc-sbc2.html which has a CS8900A on it. We've just received one, courtesy of Bill Knight, and I'll take a look at it at some point, but I'm sure CrossWorks will sprout a BSP for it real soon. Regards, -- Paul Curtis, Rowley Associates Ltd http://www.rowley.co.uk CrossWorks for MSP430, ARM, AVR and (soon) MAXQ processors > -----Original Message----- > From: Gus [mailto:gus_is_working@...] > Sent: 08 February 2005 15:43 > To: lpc2000@yahoogroups.com > Subject: [lpc2000] Re: olimex LPC-E2294 with ethernet > > > > As far as I understand, this is imposibble on the olimex > board because of the SBHE# pin. > > If I am wrong, please correct me. > > why olimex is not responding to this post? > > Gus > > --- In lpc2000@yahoogroups.com, 42Bastian Schick <bastian42@m...> > wrote: > > > I got it to work last night. The problem is that olimex board has > > > the chip connected to 16-bit data bus but it will NOT work. It > works > > > in 8-bit mode only. > > > > AFAIK, the cs8900a starts in 8bit mode, and has to be switched to > 16bit > > mode. > > But did read this only in a Phytec manual for the mpc565. > > > > > > -- > > 42Bastian Schick > > > > > > > Yahoo! Groups Links > > > > > > > > >
Message
RE: [lpc2000] Re: olimex LPC-E2294 with ethernet
2005-02-08 by Paul Curtis
Attachments
- No local attachments were found for this message.