Message

Re: more than one power supply

2002-12-03 by Mike Marsh

Hi Nathan -

I run two 900's independently and interconnect the modules with no 
trouble whatsoever. I plan to add a 950 to this, too. My limited 
understanding says that because the modules are all grounded in the 
same way, grounding is not an issue.  I have the two power supplies 
plugged into the same source (power strip) to avoid ugly buzzes.

Mike

--- In motm@y..., "Nathan Hunsicker" <nate@e...> wrote:
> Hello everybody, if I'm running more than one MOTM-900 or an 900 
and a 950,
> how would I go about connecting them? Should they be run 
completely separate
> from each other? Should they be paralleled? Should a parallel only 
the
> grounds? If I run half my modules on one supply and the other half 
on
> another, am I going to encounter any problems when patching 
modules powered
> by different supplies? I've modded my current MOTM-900 with a 
HBB15-1.5-A
> for a little more power, but I think I'll need a second PS soon. –
Nate