Easy for you to say....... hahaha Sounds like a $100. US job in America! If this one had been changed, it had been changed at the factory because I bought it from a guy who had never used it. He got it in the big sell off when Oberheim was going bust again. I used it on stage for a very short time before we retired our duo. I guess you know that Bruce Springsteen's drummer used the triggers and that was the sound they used live for at least one tour. No wasted time trying to get a "sound!" I'm glad you got it going and have many more years of that great machine! Charles Massey On Nov 20, 2007, at 6:39 AM, Damir Rogina wrote: > THIS WAS EASY > > PROBLEMATIC WAS IC U2 on perc 2 card TC4011CN > > I believe it was allready changed in past couse > soldering points didnot look like other on card so I > went to store and get IC socket to avoid soldering in > fututre if this happen again > > ( maybe this is a weak spot in DMX ??? who knows) > > I desolder new socket and instal BRAND NEW 4011CN and > SHAKER is back again alive and kicking > > > I recaped my whole DMX and noise on outputs is gone > and I belive that after allmost 25 years was time to > replace DRY caps... > > I used RIFA for PSU filtering and all other Panasonic > FC caps... > > LONG LIVE DMX probably next 20 years!!!!! > > SPECIAL THANX TO CHARLES FOR SELLING ME THIS KILLER > MACHINE !!! > > Damir K Rogina > > >
Message
Re: [oberheim] DMX lost shaker again live and kicking
2007-11-20 by Charles Massey
Attachments
- No local attachments were found for this message.