Okay, I see now. Please let us know how that turns out. Karl ________________________________ From: Omar <holografique@...> To: "xpantastic@yahoogroups.com" <xpantastic@yahoogroups.com> Sent: Sun, April 14, 2013 5:26:12 PM Subject: Re: [xpantastic] Removing the Encoder caps the issue we're referring to here has to do with new encoders, not the originals. The replacement kit that Syntaur sells uses a pot that doesn't meet the exact specs of the originals. Hence the issue. Syntaur has found a new part that does meet the original spec of "1-click per value" and I will be testing them soon. -o On Sunday, April 14, 2013, Karl Schmeer wrote: > > >Have you changed your encoders already? >The reason I ask, This is how my encoders were behaving for awhile. (multiple >clicks per Inc/Dec) >Eventually this got worse, so I pulled out my Oscilloscope and after some >checking, I found > >the schmidt trigger chips, which de-bounce the encoder signals were failing. I >replaced all of these >and it's worked fine ever since. I have never cleaned em. And they have >seen some heavy use for years now. > >Best > >Karl > >________________________________ >From: Omar <holografique@...> >To: "xpantastic@yahoogroups.com" <xpantastic@yahoogroups.com> >Sent: Sun, April 14, 2013 2:15:50 PM >Subject: Re: [xpantastic] Removing the Encoder caps > > >>yup, its two clicks for me as well, and it doesnt always happen, just seems >>random. > >snip >