Re: [xpantastic] Removing the Encoder caps

2013-04-14 by Omar

the issue we're referring to here has to do with new encoders, not the originals. The replacement kit that Syntaur sells uses a pot that doesn't meet the exact specs of the originals. Hence the issue.

Syntaur has found a new part that does meet the original spec of "1-click per value" and I will be testing them soon.

-o

On Sunday, April 14, 2013, Karl Schmeer wrote:



Have you changed your encoders already?
The reason I ask, This is how my encoders were behaving for awhile. (multiple
clicks per Inc/Dec)
Eventually this got worse, so I pulled out my Oscilloscope and after some
checking, I found

the schmidt trigger chips, which de-bounce the encoder signals were failing. I
replaced all of these
and it's worked fine ever since. I have never cleaned em. And they have
seen some heavy use for years now.

Best

Karl

________________________________
From: Omar <holografique@...>
To: "xpantastic@yahoogroups.com" <xpantastic@yahoogroups.com>
Sent: Sun, April 14, 2013 2:15:50 PM
Subject: Re: [xpantastic] Removing the Encoder caps


>yup, its two clicks for me as well, and it doesnt always happen, just seems