Re: SY-1 problem

2012-05-01 by Quazimodo

Personally Fernando, I think that your LDR is faulty - going off your findings. That is just a 20 ohm swing.

Let me get round to it and I'll try and check the LDR in my CSY-1 that I am converting here. It should be the same. I do know LDR's are many and varied, so you will need the right one, but they are readily available.

You're in no particular rush for this?

Cheers,
TOM



--- In yamahacs80@yahoogroups.com, Fernando Zarone <fernandozarone@...> wrote:
>
> Thanks;
> I have done it, Tom,
> after being disconnected, the light sensitive resistor  varies from  195 Ohm (no pressure) to 175 Ohm (max pressure)
> Is it correct in your valuable opinion?
> 
> F
> 
> Il giorno 01/mag/2012, alle ore 13:33, Quazimodo ha scritto:
> 
> > With a meter on ohms. I would disconnect the LDR from the circuit whilst checking..!
> > 
> > Cannot say what the spec should be but if there is no touch sense - there will be no meter movement...and there should be "some".
> > 
> > Cheers,
> > TOM
> > 
> > --- In yamahacs80@yahoogroups.com, "papinje" <fernandozarone@> wrote:
> > >
> > > Hello. 
> > > the touch control in a SY 1 does not work. With TC sensitivity potentiometer at its maximum, the touch controlled effects go to the maximum, but are not modified by the key pressure.
> > > Inside the machine, the lamp is lit, the "shield" moves well. What to check? How can I test the light variable resistor?
> > > Every help is appreciatedÂ…
> > > Fernando
> > >
> > 
> > 
> 
> 
> 
> [Non-text portions of this message have been removed]
>