Personally Fernando, I think that your LDR is faulty - going off your findings. That is just a 20 ohm swing. Let me get round to it and I'll try and check the LDR in my CSY-1 that I am converting here. It should be the same. I do know LDR's are many and varied, so you will need the right one, but they are readily available. You're in no particular rush for this? Cheers, TOM --- In yamahacs80@yahoogroups.com, Fernando Zarone <fernandozarone@...> wrote: > > Thanks; > I have done it, Tom, > after being disconnected, the light sensitive resistor varies from 195 Ohm (no pressure) to 175 Ohm (max pressure) > Is it correct in your valuable opinion? > > F > > Il giorno 01/mag/2012, alle ore 13:33, Quazimodo ha scritto: > > > With a meter on ohms. I would disconnect the LDR from the circuit whilst checking..! > > > > Cannot say what the spec should be but if there is no touch sense - there will be no meter movement...and there should be "some". > > > > Cheers, > > TOM > > > > --- In yamahacs80@yahoogroups.com, "papinje" <fernandozarone@> wrote: > > > > > > Hello. > > > the touch control in a SY 1 does not work. With TC sensitivity potentiometer at its maximum, the touch controlled effects go to the maximum, but are not modified by the key pressure. > > > Inside the machine, the lamp is lit, the "shield" moves well. What to check? How can I test the light variable resistor? > > > Every help is appreciatedÂ… > > > Fernando > > > > > > > > > > > [Non-text portions of this message have been removed] >
Message
Re: SY-1 problem
2012-05-01 by Quazimodo
Attachments