--- In bc2000@yahoogroups.com, sghookings@... wrote: > I had got this SPC message (in BCR2000 display) before. > What I found is this invariably related to me using the "Update changed" from the BCManager. > > If I changed to sending the full sysex, all the presets would load as expected. By "full" I think I mean the mode that sends a plethora of the .tx strings for each preset rather than the just the deltas. I'm rather mystified by "SPC". I can see it within the BCR's firmware code, but I don't know how exactly it is triggered. I suspect it's short for "SPACE", which seems to indicate that the preset being uploaded is somehow too big; that might then explain why the preset doesn't work. So it would be nice if someone could come up with a preset that consistently triggers "SPC": I could then try to find out exactly what's going wrong here. By "Update changed" you are referring to "Send modified data" from the "B-Controls" window? If "SPC" indeed only occurs during this particular operation, there might be a bug in it. Mark.