Bc2000 (for the BCF2000 & BCR2000) group photo

Yahoo Groups archive

Bc2000 (for the BCF2000 & BCR2000)

Index last updated: 2026-04-28 23:16 UTC

Message

FW: [bc2000] Re: BCR2000 no longer sending MIDI?

2013-07-09 by felix_nam

Thank you for the information...

--- In bc2000@yahoogroups.com, "felix_nam" <felix_nam@...> wrote:
>
> Hello.
> I need help,  goes out the message of mistake of the prest of mopho.
> Do you know which is the solution?
> Thank you.
> 
> Regards
> 
> --- In bc2000@yahoogroups.com, dave watkinson <dave422x@> wrote:
> >
> > Thanks again Mark.
> > 
> > I tried it in S4 mode with MIDI Out A and in S3 mode with MIDI Out B. Same thing - "No response from B-Control" and "B-Controls detected: 0".
> > I hear you on the dangerous part; I was attempting a complete reset as a last ditch attempt at recovery! ;-) The error message was exactly the same though, in both of the scenarios listed above.
> > Looks like it's time to replace it :'-(
> > Cheers for your help.
> > 
> > To: bc2000@yahoogroups.com
> > From: markwinvdb@
> > Date: Thu, 13 Dec 2012 08:04:54 +0000
> > Subject: [bc2000] Re: BCR2000 no longer sending MIDI?
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> >  
> > 
> > 
> > 
> >   
> > 
> > 
> >     
> >       
> >       
> >       --- In bc2000@yahoogroups.com, dave watkinson <dave422x@> wrote:
> > 
> > > I reconnected the BCR to my MIDI interface and put it into S3 mode. BC Manager can't detect it.
> > 
> > 
> > 
> > In mode S-3 anything received at the BCR's MIDI IN is directly routed to the BCR's MIDI OUT A.
> > 
> > 
> > 
> > So in S-3 you shouldn't use MIDI OUT A in a bidirectional setup with your computer; instead, you should use MIDI OUT B.
> > 
> > 
> > 
> > Alternatively, use MIDI OUT A under S-4.
> > 
> > (MIDI IN is routed to MIDI OUT B in this case.)
> > 
> > 
> > 
> > > Despite the lack of BCR detection (I disabled all my other USB / MIDI devices) I tried to open the Behringer default sysex file in BC Manager, and was greeted by this message:
> > 
> > > Error: MIDI system exclusive error
> > 
> > > Wrong command
> > 
> > > Send Memory ($34)
> > 
> > > This may be the result of a feedback loop
> > 
> > > Message 1
> > 
> > 
> > 
> > This is in line with what I wrote above: in S-3, BC Manager gets any message it sends to the BCR's MIDI IN straight back from MIDI OUT A.
> > 
> > 
> > 
> > Incidentally, the "Send Memory ($34)" messages contain BCR firmware data: if the BCR shows "1.10" upon power-up, there is no need whatsoever to try to update its firmware. (In fact, it's a bit dangerous.)
> > 
> > 
> > 
> > Hope this helps,
> > 
> > Mark.
> >
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.