Re: [oberheim] matrix 6 L3 IF coil transformer replacement???

2016-01-30 by Bob Grieb

That is a variable inductor, listed on the schematic as variable 
between 3 uH and 7 uH.   It is not a transformer, even though it
may look like an IF transformer.

Are you sure the old one is bad?

A quick search on the web makes me think you will have trouble 
finding an exact replacement.  Inductors add in series, so if you can find 
a slightly smaller one, then you could add a fixed inductor to it to 
get the value that you need.   You need to be able to hit a specific oscillator
frequency by adjusting the tuning slug, as described in the service 
manual.

Probably the easiest would be to get one off of a junk M6 or M6R board.

Bob


--------------------------------------------
On Fri, 1/29/16, thomas boichard yoggybeats@... [oberheim] <oberheim@yahoogroups.com> wrote:

 Subject: [oberheim] matrix 6 L3 IF coil transformer replacement???
 To: oberheim@yahoogroups.com
 Date: Friday, January 29, 2016, 7:36 PM
 
 
 
 
 
 
 
 
 
 
         
 
 
 
 
 
 
 
 
 
 
 
 
 hi!
 my
 component L3 is dead (an IF coil transformer)if you got
 infos that can help me to find another one, it would be
 dope!!!
 
 mny thanks!
 Tom/
 
 ps: it looks like this:http://www.electrojumble.org/PICS-2/L427.jpg